REGENT’S

PR11OE24

 24VDC OVER-ENERGIZER

Features:

  • Dramatically improves response time of 24V solenoids in high speed/accuracy applications.
  • Built-in fast flux decay circuit quick turn-off.
  • LED status indicator.
  • Compact size. DIN rail or panel mount.
  • Regent’s 5 Year “No-Questions-Asked” Warranty.

Ideal for:

  • Glue gun control
  • Stamping devices
  • Bag punching solenoids
  • Faulty product ejectors
  • Cutoff knives
  • Holding clamps
  • Wrap-spring clutches

The PR11OE24 is a solid-state over-energization power supply relay for 24 VDC loads. By applying an initial over-voltage, turn-on times of typical loads can be reduced by up to 75%. By reducing the load response time, cycle rates in high-speed applications can be increased dramatically.

In addition to solenoid valves, the PR11OE24 can be used to rapidly energize wrap-spring clutch solenoids. An added benefit is improved turn-on consistency.

DIMENSIONS

WIRING DIAGRAM

OPERATION
Upon initiation, the PR11OE24 supplies 150 VDC (peak) to the load, resulting in fast energization. Following over-energization, the solid-state output pole remains ON. Customer-supplied 24 VDC keeps the load energized.

The PR11OE24’s fast flux decay circuit provides fast turn-off of the load when the initiate signal is removed. No protective components are needed with inductive loads.

TYPICAL SOLENOID VALVE RESPONSE TIMES

Valve

Turn-On Time

Without With

PR11OE24 PR11OE24

Turn-Off

Time

24 watts

8.5 watts

4 watts

9 msec 3.5 msec

6 msec 2 msec

8 msec 2 msec

5 msec

4 msec

7 msec

NOTES
1. Initiating contact may be any switch, transistor, photo or proximity sensor, or PLC output capable of switching 10 mA at 24 VDC. Current sourcing or sinking can be used.
2. Load must not be grounded. Terminal 2 may be grounded if connected to a separate 24 VDC power supply.
3. Turn-off time can be reduced by installing a resistor between 24 VDC supply and +24 IN terminal to reduce holding current. Initial over-energization voltage will not be affected.

SPECIFICATIONS

PR11OE24

Line Input (L1,L2)

Recommended fuse

120 VAC +/- 20%, 50/60 Hz

Wickmann 231 2A or Littelfuse 322002

Logic Input (+1,-2)

24 VDC +/- 10%, 10 mA burden

Output (LOAD +,-)

Rating

Over-energization voltage

On-state voltage drop

Off-state leakage current

Load resistance

 

24 VDC, 1A maximum

150 V peak (at 120 VAC Line)

2 VDC max

less than 500 uA

24 ohms min, 500 ohms max

Recharge Time

Approx. 60 msec to 90% (load dependent)

Temperature

0 to 65C (32 to 149F)

    Product Name+   Price   Buy Now 
 PR11OE24   $195.00 
  Buy Now  
 
Displaying 1 to 1 (of 1 products) Result Pages:  1