SEARCH
 
 
Advanced Search
 
PRODUCTS
 
 
INFORMATION
 
Shopping Cart
Checkout
Your Account
Contact Us
 

  Regent Controls Inc.
   1 Riverside Drive
   Ansonia, CT 06401
   email:info@regentcontrols.com
   Tel: 800-243-3141, 203-732-6200
   Fax: 203-732-6300

Untitled Document

REGENT’S

eMAX™

 EMERGENCY-STOP/GATE MONITOR SAFETY RELAY

Features:

  • Can be used as single channel E-stop or safety gate monitor relay.
  • Provides 2 safe outputs.
  • Prevents machine restart if there has been an internal component failure.
  • Extremely compact 22.5mm DIN rail or panel mount package.
  • Electrical isolation between input and output.
  • Switches AC or DC loads.
  • LED status indicators.
  • Regent’s 1 Year “No-Questions-Asked” Warranty.

Ideal for:

  • E-Stop circuits
  • Safety gate monitoring
  • Machine guarding

The eMAX emergency-stop safety relay provides two safe output contacts when used with a single channel E-stop button. It uses positive-guided relays, configured for self-checking, to inhibit machine startup in the event of an internal component failure.

With a single loop of guard switches wired in series back to the eMAX, the eMAX functions as a guard monitor safety relay. Its two safe outputs can only turn on after all guards are in place and a start button has been pressed. As in E-stop mode, the eMAX will prevent machine startup in the event of an internal component failure. The eMAX can switch either AC or DC loads and comes in a 22.5mm, DIN rail mountable package.

DIMENSIONS

WIRING DIAGRAM

NOTES
1. Unit must be installed in IP54 type enclosure.
2. Unit conforms to Pollution Degree II.
3. A primary disconnect device that meets EN requirements must be installed.
4. Wiring insulation of connected devices must be rated for 250 VAC.
5. Metal housings on connected devices must be connected to PE ground circuit.
6. If a fault occurs in the safe state, the system must not be used until the problem is corrected.
7. Correct use of this control device is an essential part of proper machine cycle control.
8. Failure to follow all instructions could lead to serious bodily injury or death.
9. Maintenance to be done by Regent personnel only. Attempts to repair or modify this product voids the warranty.

SPECIFICATIONS

eMAX

CONTROL INPUTS (+,-/1,2)

Voltage

Recommended fuse

 

24 VDC +/- 20%, 100 mA burden

1/4A, 250V, 5X20mm, F

OUTPUT CONTACTS (A,B/C,D)

Rating

Response time

 

Recommended fuse

 

230 VAC/60 VDC, 6A (resistive)

ON: <35 msec

OFF: <35 msec

4A, 250V, 5X20mm, F/T

ENVIRONMENTAL

Temperature

Humidity

Altitude

 

0 to 65C (32 to 149F)

30-95%

up to 1000m above sea level

Warranty

1 year


Note: Transient protection is recommended across inductive loads.
    Product Name+   Price   Buy Now 
 eMAX24   $240.00 
  Buy Now  
 
Displaying 1 to 1 (of 1 products) Result Pages:  1