SEARCH
 
 
Advanced Search
 
PRODUCTS
 
 
INFORMATION
 
Shopping Cart
Checkout
Your Account
Contact Us
 

  Regent Controls Inc.
   1 Riverside Drive
   Ansonia, CT 06401
   email:info@regentcontrols.com
   Tel: 800-243-3141, 203-732-6200
   Fax: 203-732-6300

Untitled Document

REGENT’S

Force™

 TWO-CHANNEL TORQUE CONTROL

Force90/24-120 for 120 VAC Logic
Force90/24-32 for DC Logic

Features:

  • Self-contained manual torque control.
  • Adjustable torque settings (from 5% to 100%) with dials on unit.
  • Increases clutch/brake life with adjustable switching time delay.
  • Isolated logic input for load control.
  • Compact size. DIN rail or panel mount.
  • LED load status indicators.
  • Regent’s 5 Year “No-Questions-Asked” Warranty.

Ideal for:

  • Converting machinery
  • Web feed control
  • Packaging machinery
  • Tension control


The Force90 and Force24 Torque Controls provide manual torque adjustment for 90 VDC or 24 VDC clutches and brakes.

When power is applied to the control, the brake is on and the clutch is off. When a logic signal is applied, the brake turns off and the clutch turns on. Torque levels of the brake and clutch are independently adjustable.

Isolated logic input permits direct interface with PLC output modules, photoelectric controls, contacts, etc.

Adjustable switching time delay lets you minimize overlap between the clutch and brake. Reduced overlap means longer mechanical life.


DIMENSIONS




WIRING DIAGRAM: Force24




WIRING DIAGRAM: Force90

NOTE
1. Logic terminals 1,2 are isolated. Terminal L2 or T2 and/or 2 may be grounded.

2. Load terminals A,B,C are not isolated from line terminals L1,L2 or T1,T2 and must not be connected to ground.

3. Do not place switches or mechanical contacts between load terminals A,B,C and the load. Opening these circuits while current is flowing may damage the control.

For 90 VDC Clutch/Brake (Force90):

SPECIFICATIONS

Force90-120

Force90-32

Line Input (L1,L2)

120 VAC +/- 20%, 50/60 Hz

25 mA burden (excluding load)

120 VAC +/- 20%, 50/60 Hz

25 mA burden (excluding load)

Logic Input (1,2)

120 VAC +/- 20%, 50/60 Hz,

25 mA burden (will not operate on leakage current below 10 mA)

3-32 VDC,

1-35 mA burden

Load Rating (A,B,C)

Output current

Adjustable from 5 to 100% of full load

1 A maximum

Adjustable from 5 to 100% of full load

1 A maximum

Switching Time Delay (RT,RT)

Adjustable from less than 1 to 100 msec

Adjustable from less than 1 to 100 msec

Recommended Line Fuse

Littelfuse 322002

Littelfuse 322002

Temperature

0 to 65C (32 to 149F)

0 to 65C (32 to 149F)

For 24 VDC Clutch/Brake (Force24):

SPECIFICATIONS

Force24-120

Force24-32

Line Input (T1,T2)

24 VDC +/- 2 VDC or

28 VAC +/- 20%, 50/60 Hz

35 mA burden (excluding load)

24 VDC +/- 2 VDC or

28 VAC +/- 20%, 50/60 Hz

35 mA burden (excluding load)

Logic Input (1,2)

120 VAC +/- 20%, 50/60 Hz,

25 mA burden (will not operate on leakage current below 10 mA)

3-32 VDC,

1-35 mA burden

Load Rating (A,B,C)

Output current

Adjustable from 5 to 100% of full load

1.5 A maximum

Adjustable from 5 to 100% of full load

1.5 A maximum

Switching Time Delay (RT,RT)

Adjustable from less than 1 to 100 msec

Adjustable from less than 1 to 100 msec

Recommended Line Fuse

Littelfuse 322005

Littelfuse 322005

Temperature

0 to 65C (32 to 149F)

0 to 65C (32 to 149F)

    Product Name+   Price   Buy Now 
 Force24-120   $300.00 
  Buy Now  
 
 Force24-32   $300.00 
  Buy Now  
 
 Force90-120   $300.00 
  Buy Now  
 
 Force90-32   $300.00 
  Buy Now  
 
Displaying 1 to 4 (of 4 products) Result Pages:  1